Rockwell Automatisation no longer supplies new units. Items available on the market are second-hand, refurbished or spare stock. It is a classic legacy monochrome IHM of the PanelView Standard 550 série.
✅ Model Breakdown
2711-T5A2L1
2711: PanelView Standard series
T: Touchscreen only (no membrane keypad)
5: 5.5-inch display
UN: Monochrome LCD (noir & blanc)
2: DH-485 communication port, no print port
L1: 24V DC power supply version
📋 Core Technical Specifications
| Article | Caractéristiques |
| Afficher | 5.5-inch monochrome LCD, resistive touchscreen |
| Alimentation | 18~30 V CC, rated 24VDC; Max 12W, 0.5A@24V |
| Communication | DH‑485 (for connection with legacy AB SLC500, MicroLogix PLCs) |
| Mémoire | Non-volatile memory 240KB / RAM 170KB |
| Montage | Panel cutout mounting, front panel IP65 |
| Logiciel de programmation | PanelBuilder32 (legacy software, 32-bit OS only) |
| Firmware Versions | Common A series, micrologiciel 3.30/4.41 etc.. |
| Température de fonctionnement | 0~55℃ |
| Unavailable Ports | No print port, pas d'Ethernet |
📌 Typical Applications
Legacy production line retrofits, machines d'emballage, manutention des matériaux, traitement de l'eau, and older SLC500/MicroLogix projects. DH485 bus only, no EtherNet/IP support.
⚠️ Common Failures & Des pièces de rechange
- Backlight degradation: Most typical fault. Spare part 2711-NL1 (CCFL backlight tube; LED backlight modification is also feasible)
- Panneau tactile endommagé: PV550 touch membrane can be replaced separately
- Perte de programme: On-board coin cell battery preserves screen programs; program loss occurs once battery fails
- Échec de communication: DH485 bus termination resistor, wiring polarity, RSLinx driver issues
🔁 Replacement Options for Engineering Retrofit
Original project cannot be migrated directly, screen reconfiguration is mandatory
- Preferred direct replacement: 2711R-T4T / 2711R-T7T (Vue du panneau 800). Supports RS485 and connects to legacy PLCs;
- Modern alternative: PanelViewPlus 7 / Vue du panneau 5000 series with Ethernet port;
- 3rd-party domestic HMI: Weintek / Kunlun MT, connecting legacy AB controllers via DH485/Modbus with lower cost.
📎 Supporting Documentation
Manuel: 2711-UM014 (PanelView Standard Terminal User Manual)
Datasheet: 2711-TD007
Référence du code SH
85287110 (Industrial touchscreen, IHM, applicable for customs declaration)
2711-T5A2L1 (Vue du panneau 550) Old-to-New HMI Program Migration Assessment Checklist
En vigueur: Migration from legacy AB PanelView Standard 550 to PanelView 800 / PanelViewPlus / 3rd-party domestic HMI
Point clé: PanelBuilder32 project cannot be imported into new HMI software; full reconfiguration required. This checklist is used for pre-migration risk assessment and workload estimation.
- Matériel & Communication Assessment
| Assessment Item | Inspection Content | Risk Notes |
| Original Controller Model | SLC500 / MicroLogix 1000/1100/1200/1500? | Legacy PLC only supports DH485; verify whether new HMI has native DH485, otherwise protocol converter required |
| Protocole de communication | Original: DH485 | New HMI options: DH485 / DF1 / Modbus RTU (PLC side must support) |
| Address Mapping | Original PV550 tags: N, B, T, C, R., F and other PLC registers | ⚠️ Register addresses must be checked line by line, do not copy by experience; distinguish bits / mots / floats |
| Câblage des communications | Existing DH485 bus, termination resistors, wiring polarity | New HMI communication interface differs, evaluate rewiring and additional converter workload |
| Alimentation | 24VCC | Most old & new units compatible; verify terminal definition and fuse rating |
| Panel Cutout Dimension | 2711-T5A2L1 cutout: 216 × 152mm | New HMI dimension differs; evaluate: remplacement direct / adapter plate / cabinet cutout modification |
| Environnement d'installation | Température, poussière, vibration | Verify new HMI environmental rating and IP protection match site conditions |
- Original HMI Project Inventory (Export from PanelBuilder32)
| Assessment Item | Inspection Content | Remarques |
| Total Screen Count | Main screen, manual mode, alarme, parameter, trend | Count screens to estimate configuration man-hours |
| Screen Element List | Buttons, indicateurs, numeric displays, input boxes, sélecteurs | Distinguish bit read/write, word read/write, multi-state indicators |
| Alarm Information | Alarm text, trigger bit, acknowledge bit, alarm log | ⚠️ PV550 uses simple bit-triggered alarms; new HMI alarm storage capacity varies |
| Recipe Function | Recipe used or not? | PV550 recipes stored locally in HMI; re-plan recipe storage location (IHM / API) for new HMI |
| Trend Curves | Real-time / historical trend, sampling cycle | Legacy PV550 only supports simple real-time trend without large-capacity history logging; evaluate history storage for new HMI |
| Security Access | Password, user level, screen access permission | Vieux & new permission models differ; recreate user accounts |
| Macro / Script Logic | PanelBuilder32 built-in macros | High risk: Macros cannot be migrated. All logic must be rewritten using new software scripts / fonctions |
| Screen Switch Logic | Screen jump buttons, conditional jump | Replicate conditional jump logic line by line |
| Print Function | This 2711-T5A2L1 model has no print port, skip this item | Evaluate printing if other models in the series are used |
| Hardcopy / Screenshot | Screen capture function required? | Configure on demand for new HMI |
III. Tag / Variable Mapping Assessment (Core Workload Item)
- Export full variable list of original project (print variable table in PB32)
- Classification & statistics:
Boolean (Peu: Courir, Faute, Auto/Manual, Alarms)
Integer (Word: Setpoints, Counters)
Float (Température, Pression)
- Verify PLC data file types: N files, B files, T/C preset values, registers
- Mark special variables:
Arrays
Indirect addressing (High risk: many new HMIs do not support legacy AB indirect addressing syntax)
Read-only / Read-write attributes
Risk note: DH485 address notation differs between HMI software packages, prone to address offset errors.
- Function Equivalence Assessment (Item-by-item comparison, mark missing functions)
| Original PV550 Function | Remarques |
| Bit buttons, momentané / latching buttons | Distinguish momentary pushbuttons (most common error source) |
| Multi-state indicators (3-État / multi-state) | |
| Numeric input, limit validation | PV550 local limit check; new HMI can validate on HMI side or PLC side |
| Screen jump, conditional jump | Test conditional jump logic |
| Alarm trigger, alarm acknowledge | Alarm text encoding (Chinois / Anglais; legacy units mostly English) |
| Recipe read/write | Verify recipe quantity and data length |
| Real-time trend | Cycle d'échantillonnage, channel quantity |
| User password permission | Password hierarchy, lock function |
| Macro logic | Decompose macro logic and implement via PLC logic or new HMI scripts |
- PLC Side Change Assessment
Whether PLC program modification is required to adapt new HMI communication
Whether spare PLC register space is available for new HMI functions (recipes, history logging)
Whether PLC firmware supports new protocols (par exemple. DF1)
Downtime window assessment for PLC program download
- Test Plan Assessment
- Offline simulation: Simulate screens and variables in HMI software, verify addresses
- Bench test: New HMI + identical site PLC bench commissioning (recommended to reduce on-site downtime)
- Step-by-step on-site power-up test:
Communication connectivity test
All screen switching
Full button operation & indicator feedback
Parameter write / read verification
Alarm trigger & acknowledge test
Recipe read/write test
- Long-term aging test (facultatif)
- Rollback plan: Keep old HMI, mark wiring for fast fallback in case of failure
VII. Documentation & Delivery Assessment
Backup of new HMI project source file
Variable cross-reference table (old tags ↔ new HMI variables)
Screen function specification document
Updated wiring diagram (HMI terminals, communication bus)
Updated site operation manual
Spare parts list (new HMI spare parts, module de communication)
VIII. Risk Summary & Man-hour Estimation
Fill directly into assessment form
- High-risk items: Macro logic, indirect addressing, address misalignment
- Medium-risk items: Alarm logic, recipes, communication parameter mismatch
- Low-risk items: Screen layout, static text
Man-hour reference:
10 basic screens without complex macros/recipes: estimated 1~2 working days for configuration + essai; projects with heavy macros, recipes, indirect addressing require double the man-hours.
- Downtime Plan Assessment
Planned downtime window duration
Wiring modification time
Commissioning time
Emergency plan & rollback scheme
Rockwell Allen-Bradley PanelView HMI Full Series List
Grouped by generation, marked【Active / Discontinued】, with supporting software and key features. Optimized for your 2711-T5A2L1 legacy screen retrofit selection
Catalog rule: 2711 = legacy classic; 2711R=PanelView800; 2711P=PanelView Plus; 2715=PanelView5000; 2800=OptixPanel
- Legacy Classic Series (All discontinued, second-hand/spare market; your 2711-T5A2L1 belongs here)
1.1 PanelView Standard (2711 série, monochrome / early color, PanelBuilder32 software)
Vue du panneau 300: 2711-T3A / 2711-K3A, 3-inch monochrome, DH485
Vue du panneau 550: 2711-T5A2L1 / 2711-K5A2L1, 5.5-inch monochrome (votre modèle)
Vue du panneau 600: 2711-T6C / 2711-K6C, 6-inch color
Vue du panneau 900: 2711-T9C / 2711-K9C, 9-inch color
Vue du panneau 1000: 2711-T10C / 2711-K10C, 10-inch color
Communication: DH485, DF1; Pas d'Ethernet; Logiciel de programmation: PanelBuilder32 (32-bit Windows only)
Typical faults: CCFL backlight aging, on-board coin cell causing program loss
1.2 PanelView Component (2711C, Discontinué)
2711C-C200, miniature modular HMI, paired with Micro800 compact PLC, simple screens
1.3 Early Generation PanelView Plus (First-gen 2711P, Discontinué)
Original PV Plus, Grimacer, FactoryTalk Voir ME, 600/700/1000/1250/1500
- Previous Generation: PanelViewPlus 6 (2711P., EOL Discontinued, existing installed base)
Logiciel: FactoryTalk View Machine Edition (FTView ME), WinCE6.0
PV Plus6 400: 2711P-T4C / K4C, 4-pouce
PV Plus6 600: 2711P-T6C / K6C, 6.5-pouce
PV Plus6 700: 2711P-T7C / K7C, 7-pouce
PV Plus6 1000: 2711P-T10C / K10C, 10.4-pouce
PV Plus6 1250: 2711P-T12C / K12C, 12.1-pouce
PV Plus6 1500: 2711P-T15C / K15C, 15-pouce
Suffix explanation: T=Touch; K=Membrane Keypad; C=Color; D=DC power; A=AC power
- Active Classic: PanelViewPlus 7 (2711P., Active for Sale), Standard / Performance versions
Logiciel: FactoryTalk Voir ME; Performance version runs Win10 IoT Core, supports video, VNC, DLR ring
Version standard: 4”,7”,10”,12”,15”
Exemples: 2711P-T4W21D8S, 2711P-T7C21D8S, 2711P-T10C21D8S, 2711P-T12W21D8S, 2711P-T15C21D8S
Performance high-performance version: 7~19” wide screen, stainless steel enclosure, conformal coated ArmorView machine-mount type
Exemples: 2711P-T7C22D9P, 2711P-T10W22D9P, 2711P-T15C22D9P, 2711P-T19C22D9P
- Economy Small Size: Vue du panneau 800 (2711R., Active for Sale), Preferred replacement for legacy DH485 projects
Logiciel: FactoryTalk View 800 (lightweight standalone software); Ethernet + RS485/DF1 native support, perfect for SLC500/MicroLogix, recommended replacement for your 2711-T5A2L1
2711R-T4T: 4.3-inch touch
2711R-T7T: 7-inch touch
2711R-T10T: 10.4-inch touch
Touch-only models, rentable, popular for legacy line retrofit
- New High-End Platform PanelView 5000 (2715 série, Active for Sale), for Logix5000: ControlLogix/CompactLogix
Logiciel: Studio5000 View Designer (integrated into Studio5000, FTView ME incompatible), native EtherNet/IP for large automation projects
- Vue du panneau 5310 (2713P., basique): 4”,7”,10”,12”,15”
Exemple: 2713P-T10CD
- Vue du panneau 5510 (2715P., haute performance):7/10/12/15/19”, touche / keypad hybrid
Exemple: 2715P-T7CD, 2715P-T10CD, 2715P-T15CD
⚠️Critical reminder: PV5000 project is fully incompatible with PanelView Plus projects, screen migration impossible
- Nouvelle génération: OptixPanel (2800 série, Rockwell new HMI, Active for Sale)
Successor to PanelView 800 doubler, Compact and Standard models, FactoryTalk Optix software, native IoT & edge visualization
OptixPanel Compact (2800C): 2800C-070AS-1S (7-pouce)
OptixPanel Standard (2800S):7/10/12/15-pouce
Designed for new projects, weak native DH485 serial support, not recommended for direct replacement of legacy 2711 écrans
- Mobile Handheld HMI: MobileView (2711T)
Cabled pendant handheld operator terminal for machine-side operation, 2711T series, partial models available.
- Industrial Panel PC (Not pure touchscreen, industrial all-in-one PC, ASEM series)
6300P., 6300M series industrial panel PCs, Système d'exploitation Windows, for local advanced SCADA operation
Series Selection Comparison Table (Quick reference for retrofit projects)
| Série | Catalog Number | Cycle de vie | Logiciel de configuration | Scénarios d'application |
| PanelView Standard | 2711 | Discontinué | PanelBuilder32 | Legacy spare part maintenance (2711-T5A2L1) |
| PanelView Plus6 | 2711P. | Discontinué | FTView ME | Spare parts for existing installed base |
| PanelView Plus7 | 2711P. | Actif | FTView ME | Moyen & large production lines, compatible with legacy FT projects |
| Vue du panneau 800 | 2711R. | Actif | FTView800 | ✅Legacy DH485 line retrofit, replace 2711-T5A2L1 |
| PanelView5000 | 2713P/2715P | Actif | Studio5000 View Designer | Large Logix5000 projects |
| OptixPanel | 2800 | Actif | FactoryTalk Optix | Nouveaux projets, IoT visualization |
General Suffix Definition (Rapid model decoding)
T = Touch only; K = Keypad membrane; B = Touch + Keypad combined
C = Color LCD; A=Monochrome
D = 24VDC supply; A=AC100-240V
W = Wide screen; P = Performance high grade
S = Standard grade
Key Project Migration Tips (Continued from your 2711-T5A2L1 migration assessment)
- 2711 (PV Standard) → 2711R PanelView800: Recommandé, supports RS485/DF1 for SLC500/MicroLogix, coût modéré; screens must be reconfigured, PB32 project cannot be imported
- 2711 → PanelView Plus7: Also feasible, requires DF1 / serial communication module
- 2711 → PanelView5000: Not recommended for legacy DH485 retrofit. Software fully different, extra gateway required for serial port, heavy engineering workload
Contacteur,disjoncteur,capteur,Encodeur,API,Convertisseur