Contacteur magnétique Mitsubishi S-T35 AC

The S-T35 belongs to Mitsubishi MS-T Series, the upgraded successor model of S-N35, which is fully interchangeable with S-N35. It is an AC coil driven contactor widely used for three-phase motor start-stop and power circuit control in control cabinets. ✅ Core Specifications Frame size: 35 cadre, 3-pole main contacts AC-3 rating at 380/400V: 18.5kW, noté ...

  • Détails du produit

The S-T35 belongs to Mitsubishi MS-T Series, the upgraded successor model of S-N35, which is fully interchangeable with S-N35. It is an AC coil driven contacteur widely used for three-phase motor start-stop and power circuit control in control cabinets.

✅ Spécifications de base

Taille du cadre: 35 cadre, 3-contacts principaux des pôles

AC-3 rating at 380/400V: 18.5kW, rated operating current 35A

Tension maximale du circuit principal: AC690V

Standard built-in auxiliary contacts: 2NON + 2Caroline du Nord (2a2b)

Dimensions hors tout: 75(W) × 89(H) × 91(D) mm, weight 0.55kg

Montage: DIN rail mounting or screw fixing; mounting hole positions fully compatible with S-N35

Classe de protection: IP20

Endurance mécanique: 10 millions d'opérations; Endurance électrique (AC-3): environ. 1 millions d'opérations

Coil voltage options (AC standard): AC24V, AC110V, AC220V, AC380V, AC400V, AC500V, 50/60Hz universel

✅ Model Naming Rule

`S-T35 + Coil Voltage`

Exemple: S-T35 AC220V, S-T35 AC380V

Note: S-T series is AC coil by default. DC coil version is SD-T series; do not mix them up.

✅ Comparison with S-N35

Courant nominal du contact principal, power rating and auxiliary contact configuration are identical

Mounting dimensions and drilling holes are interchangeable for direct replacement

Optimized coil pull-in performance, wider voltage tolerance range and lower power consumption; officially recommended replacement for S-N35

✅ Matching Accessories

Modules de contacts auxiliaires: UA, UN series (for contact expansion)

Suppresseur de surtension: Série SZ (varistance / RC absorber to suppress coil back EMF)

Relais de surcharge thermique: TH-T35 (motor overload protection, assorti pour 35 cadre)

Mechanical interlock unit: used for forward/reverse (inversion) circuit

✅ Scénarios d'application typiques

Presses à injecter, les fans & pompes à eau, lignes de production, compresseurs d'air, Armoires de commande CVC, circuits électriques de machines-outils, direct start-stop control of three-phase asynchronous motors.

✅ Troubleshooting Guide

  1. Coil energized but no pull-in: Vérifier la tension de la bobine, check loose wiring, test burnt coil
  2. Humming noise after pull-in: Undervoltage supply, dust/rust on iron core mating surfaces
  3. Severe main contact arcing & brûlant: Overload beyond AC-3 rating, perte de phase, frequent switching, damaged arc shield
  4. Unstable auxiliary contact signals: Oxidized contact surface, insufficient terminal tightening torque

✅ Cross-Brand Equivalent Models

Schneider LC1D38, Siemens 3RT2035, OMRON CJX2-32

  1. Terminal Definition of S-T35 (Standard 2a2b)

Circuit principal (Incoming top, outgoing bottom)

L1, L2, L3 (Power supply side); T1, T2, T3 (Load side, connected to TH-T35 thermal relay input terminals)

Bornes de bobine

A1, A2: Bobine CA. Two A2 terminals are internally shorted for easy jumper wiring.

Contacts auxiliaires intégrés (2NON+2NC)

✅ Normally Open (NON): 13-14, 43-44

✅ Normally Closed (Caroline du Nord): 21-22, 31-32

Screw size: Main circuit M4; Bobine & auxiliary contacts M3.5

  1. Basic Self-Locking Wiring Diagram (S-T35 + TH-T35 Thermal Relay, Motor Start-Stop)

Circuit principal

3-phase power → Circuit breaker → S-T35 L1/L2/L3 → S-T35 T1/T2/T3 → TH-T35 thermal relay input → Thermal relay output → Motor M

Circuit de contrôle (AC220V example)

  1. L → Stop button (Caroline du Nord) → Bouton Démarrer (NON) → S-T35 A1
  2. N → S-T35 A2
  3. Self-locking: Parallèle 13-14 (NON) across the start button
  4. Protection contre les surcharges: Wire TH-T35 95-96 (Caroline du Nord) in series into the control circuit; the coil will cut off when overload trips

Full Model List of MS-T Series

1) Non-Reversing Standard Models (S-T, your S-T35 is included)

ModèleCourant AC-3 (380V)Puissance du moteur (380V)Contacts auxiliaires standards
S-T1011UN5.5kW1a1b
S-T1213UN7.5kW1a1b
S-T2018UN7.5kW1a1b
S-T2121UN11kW2a2b
S-T2525UN11kW2a2b
S-T3232UN15kW2a2b
S-T3535UN18.5kW2a2b
S-T5050UN22kW2a2b
S-T6565UN30kW2a2b
S-T8080UN37kW2a2b
S-T100100UN45kW2a2b

Coil suffix options: AC24V / AC110V / AC220V / AC380V; par exemple. S-T35 AC220V

2) Inversion (Avant/Arrière) Integrated Models (S-2×T with built-in interlock)

S-2×T10, S-2×T12, S-2×T20, S-2×T21, S-2×T25, S-2×T32, S-2×T35, S-2×T50, S-2×T65, S-2×T80, S-2×T100

3) Modèles dérivés spéciaux (Même cadre, structure différente)

  1. DC Coil Version (SD-T, not interchangeable with S-T)

SD-T10, SD-T12, SD-T20, SD-T21, SD-T25, SD-T32, SD-T35, SD-T50, SD-T65, SD-T80, SD-T100

  1. Mechanical Latching Type (SL-T): Pull-in on energization, keep closed after power cut; only released when control circuit is disconnected

SL-T21, SL-T35, SL-T50, SL-T65, SL-T80, SL-T100

  1. Off-Delay Release Type (S-T□DL)

S-T12DL, S-T21DL, S-T35DL

  1. Matching Thermal Overload Relays (TH-T Series, frame-matched one-to-one)

TH-T18 (for T10/T12/T20)

TH-T25 (for T21/T25/T32)

TH-T35 (for S-T35)

TH-T50 (for T50)

TH-T65 (for T65/T80)

TH-T100 (for T100)

III. Magnetic Starters (Integrated contactor + relais thermique)

Non-reversing: MSO-T10, MSO-T12, MSO-T20, MSO-T21, MSO-T25, MSO-T32, MSO-T35, MSO-T50, MSO-T65, MSO-T80, MSO-T100

Inversion: MSO-2×T10 …… MSO-2×T100

  1. Règle de dénomination du modèle (S-T□)

S = Contactor

T = MS-T Series (replaces old S-N series)

Numeral = Frame current rating (10/12/20/21/25/32/35/50/65/80/100)

Suffixe: Tension de bobine (AC220V/AC380V); DL = Off-delay release; SL = Mechanical latch; SD = DC coil

  1. Cross-Replacement Table with Old S-N Series (Remplacement direct)

S-T10 ↔ S-N10

S-T12 ↔ S-N12

S-T20 ↔ S-N20

S-T21 ↔ S-N21

S-T25 ↔ S-N25

S-T32 ↔ S-N32

S-T35 ↔ S-N35 (votre modèle)

S-T50 ↔ S-N50

S-T65 ↔ S-N65

S-T80 ↔ S-N80

S-T100 ↔ S-N100